Product Description
Tripp Lite’s SUTX20KX (20kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100% system availability with 1+1 parallel capability. In 1+1 configuration , two SUTX20KX models connected in parallel can provide fail-safe redundancy (two 20kVA models supporting a 20kVA load) or increased capacity (two 20kVA models supporting an 40kVA load). The SUTX20KX provides mission-critical equipment with the highest level of power protection available. Large capacity 20,000VA/16,000W UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time assures compatibility with all equipment types. High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology produce less than 3% input total harmonic distortion (THDi). With low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to the equipment load (1:1 ratio). Extremely efficient operation (up to 97%) saves money by lowering electricity consumption. Hardwire input and output connections support a variety of permanent or PDU-style power connections. The SU20KX features 50 or 60 Hz (auto-selectable) frequency. The SU20KX combines internal power and battery modules in a single small-footprint tower compartment. Typical half-load/full-load runtimes are 13 min./5.5 min. Battery runtime can be extended with optional stand-alone hardwired external battery modules (Models BP480V26B and BP480V40C, available separately). A manual bypass breaker and an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power if the UPS requires maintenance.
Tripp Lite SUTX20KX Features
- 1+1 configuration: Two SUTX20KX can be connected in parallel to provide either fail-safe redundancy or increased capacity
- Low THDi (less than 3%) reduces installation costs by allowing 1:1 generator sizing
- Extremely efficient operation (up to 97%) saves money by reducing electricity consumption
- True on-line, double-conversion UPS with IGBT technology provides pure sine wave AC output at all times
- Maintains continuous operation with zero transfer time through blackouts, voltage fluctuations and surges
- Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
- 20,000VA/16,000W power capacity with 3-phase, hardwire input/output connections
- Wide input voltage correction range: 173-276V/300-477V AC
- Internal power and battery modules are combined in a single small-footprint tower compartment. Typical half-load/full-load runtimes are 13 min./5.5 min. Battery runtime can be extended with optional stand-alone hardwired external battery modules (Models BP480V26B and BP480V40C, available separately)
- Front panel combination LCD/LED display includes a real-time event log screen with up to 500 events listed
- Dynamic battery management screen optimizes battery function to lengthen service life and allow cold restart of the UPS
- Built-in RS-232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single server
- Accessory slot accepts an optional internal SNMP card (Model SNMPWEBCARD) for remote shutdowns, reboots and more
- Emergency Power Off button turns UPS output OFF and disables Bypass output
- Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
20000
Output kVA capacity
(kVA)
20
Expandable battery
runtime
Supports extended runtime with optional external battery packs
External battery pack
compatibility
BP480V26B; BP480V40C; BP480V55; BP480V78; BP480V103; BP480V140
Expandable runtime
description
External battery pack wiring is contractor supplied
DC system voltage
(VDC)
240
Replacement battery
cartridge (internal
UPS battery
replacement)
SURBC2030
Battery replacement
description
Hot-swappable, replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Online, double-conversion power conditioning
Overvoltage
correction
Maintains continuous operation without using battery power during overvoltages to 276-477 (3-phase, 4-wire, wye),
reducing output within 1% of nominal
Undervoltage
correction
Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300
(3-phase, 4-wire, wye)
LEDS ALARMS & SWITCHES
LED Indicators 4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions
Alarms Alarms signal a variety of operational conditions: low-battery, overload, shutdown, bypass and more
Alarm cancel
operation
Power-fail alarm can be silenced using alarm-cancel switch
Switches ON button turns UPS inverter on. OFF button turns UPS inverter off. LCD Display Control Buttons browse through
and select items displayed on LCD screen. EPO (Emergency Power Off) button turns UPS output off and disables
Bypass output
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
5950
UPS AC suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
AC suppression joule
rating
5950
AC suppression
response time
Instantaneous
PHYSICAL
Installation form
factors supported
with included
accessories
Tower
Primary form factor Tower
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / inches)
46 x 20.5 x 33.7
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / cm)
116.8 x 52.1 x 85.6
Installed whole
system maximum
rack depth (cm)
0
UPS / Power Module
weight (lbs)
588.6
UPS / Power Module
weight (kg)
267.2
UPS Shipping
dimensions (height x
width x depth / inches)
55 x 28.5 x 42.5
UPS Shipping
dimensions (height x
width x depth / cm)
139.7 x 72.4 x 108
Shipping weight (lbs) 738.5
Shipping weight (kg) 335.3
Cooling method Fans
UPS housing material Steel
ENVIRONMENTAL
Operating
Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature
Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
COMMUNICATIONS
Communications
interface
DB9 Serial; Slot for SNMP/Web interface
PowerAlert software Included
Communications
cable
DB9 cabling included
LINE / BATTERY TRANSFER
Transfer time No transfer time (0 ms.) in online, double-conversion mode
Low voltage transfer
to battery power
(setpoint)
Maintains continuous operation without using battery power during brownout/undervoltage conditions to 173-300V
AC (3-phase, 4-wire, wye). Below this point, output is maintained utilizing reserve battery power
High voltage transfer
to battery power
(setpoint)
Maintains continuous operation without using battery power during overvoltages to 276-477V AC (3-phase, 4-wire,
wye), reducing output within 1% of nominal. Above this point, output is maintained utilizing reserve battery power
SPECIAL FEATURES
Cold Start (startup in
battery mode during a
power failure)
Cold-start operation supported
High availability UPS
features
Automatic inverter bypass; Hot swappable batteries
Green & high
efficiency features
High efficiency economy mode operation; Schedulable daily hours of economy mode operation
There are no reviews yet.