Tripp Lite SVT20KX UPS

Availability:

Out of stock


  • SVT20KX SmartOnline SVTX Series 
  • 3-Phase 380/400/415V 20kVA 18kW 
  • On-Line Double-Conversion UPS, Tower,
  •  Extended Run, 
  • SNMP Option

UShs38,640,000 inc. VAT

Out of stock

Compare

Product Description

The SVT20KX SmartOnline® SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line DoubleConversion UPS with IGBT technology provides battery backup and AC power protection against power disturbances that can damage electronics or destroy data. It’s recommended for critical IT or corporate infrastructure, telecom, LAN/WAN, security and emergency, financial and light industrial applications. The SVT20KX’s Voltage and Frequency Independent (VFI) design allows continuous operation at any supported voltage at either 50 or 60 Hz. Zero transfer time to battery mode ensures no disruption to the attached loads. Automatic and Manual Bypass keeps connected equipment powered even during overloads and UPS maintenance. IGBT inverter technology produces output power with less than 2% total harmonic distortion (THD) to keep connected equipment functioning at its peak. A 3:1 crest factor safely supports a variety of loads, even those with wildly fluctuating power demands. Managing the SVT20KX is simplified through the interactive front-panel LCD interface, which displays critical operating conditions and diagnostic data, such as load levels, available runtime, alarm status, battery charge, and voltage and frequency values. Four LEDs indicate bypass, line, battery and fault modes. A serial port allows connection to Tripp Lite’s free local shutdown agent. A built-in card slot supports WEBCARDLX or RELAYCARDSV for network interface and remote monitoring and control. The SVT20KX’s reduced size and small footprint save valuable space.

Tripp Lite SVT20KX Features

VFI True On-Line Double-Conversion 3-Phase UPS System

  • On-line double-conversion topology, VFI operation
  • Automatic and Manual Bypass for enhanced reliability
  • Optional ECO mode for highefficiency operation
  • Internal batteries and expandable runtime options
  • Paralleling capability of up to 3 units

Package Includes

  • SVT20KX SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line DoubleConversion UPS
  • (2) RS-232 cables
  • 6-pin current sharing cable
  • Owner’s manual
    1 / 6
  • Provides fully regulated sine wave AC output for critical telecom, network, security, financial, corporate
    and light industrial applications
  • +/-1% output voltage regulation in online and battery modes
  • High 0.9 power factor offers 20kVA/18kW output capacity, allowing for more connected devices
  • Selectable 380/400/415V output voltage
  • Wide input voltage window (305–478V) minimizes battery use and prolongs battery life
  • Reliable Battery Backup with Expandable Runtime
  • Supports half load for 11 min. and full load for 4 min.
  • Zero transfer time suitable for advanced network applications
  • Expandable runtime with optional external battery packs, such as Tripp Lite’s BP240V135
  • Restarts automatically after lengthy power outages

IGBT Inverter Technology

  • Produces output power with less than 2% THD to keep connected equipment functioning at its peak
  • Low <6% THDi input rating and advanced IGBT rectifier enables 1:1 Generator Sizing, eliminating costly oversizing requirements for generators, breakers and cables

Paralleling Capability

  • Connect up to 3 units in parallel configuration for increased capacity and fault tolerance
  • Automatic and Manual Bypass
  • Increases system reliability
  • Allows maintenance without removing power from attached loads

ECO Mode

  • Operates at efficiency levels as high as 98.8% when input line conditions are favorable
    SNMP/Web Capability
  • Slot for WEBCARDLX network interface or RELAYCARDSV relay card for remote monitoring and
    control options

Communications Ports

  • DB9 and EPO ports offer local monitoring and shutdown options
  • Small-Footprint Tower Design
  • Reduced-size black tower case saves valuable floor space
  • Matching external battery cabinets enable extended runtime options
Categories: , Tags: , ,

Specifications

MODEL TEXT

Key Benefit Economical, entry-level 3-phase UPS system protects connected mission-critical equipment against damage,

downtime and data loss due to blackouts, brownouts, power surges and line noise.

OUTPUT

Output Volt Amp Capacity (VA) 20000

Output kVA Capacity (kVA) 20

Output kW Capacity (kW) 18

Output Capacity Details Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to

130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is

automatically restored as load levels are reduced to 70% or less; Configuration options support up to 3 SVT20KX

systems wired in parallel for increased capacity or fault-tolerant, redundant operation

Power Factor 0.9

Crest Factor 3:1

Nominal Output Voltage(s)

Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye

Frequency Compatibility 50 / 60 Hz

Output Voltage Regulation (Line

Mode) +/- 1%

Output Voltage Regulation

(Economy Line Mode) +/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V)

Output Voltage Regulation (Battery

Mode) +/- 2%

Output Receptacles Hardwire

Output AC Waveform (AC Mode) Pure Sine wave

Output AC Waveform (Battery

Mode) Pure Sine wave

INPUT

Rated input current (Maximum Load) 34.4A

Nominal Input Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye

Nominal Input Voltage Description 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)

UPS Input Connection Type Hardwire

Input Circuit Breakers 63A (3 pole)

Input Phase 3-Phase

Power Factor (Input) .99PF (100% load)

THDi <6% (100% load)

3 / 6

BATTERY

Full Load Runtime (min.) 4 min (18kW)

Half Load Runtime (min.) 11 min. (9kW)

Expandable Battery Runtime Supports extended runtime optional external battery packs

External Battery Pack Compatibility BP240V135

DC System Voltage (VDC) 240

Battery Recharge Rate (Included

Batteries) 4 hours to 90% (Internal batteries)

Expandable Runtime Yes

VOLTAGE REGULATION

Voltage Regulation Description Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online

mode

Overvoltage Correction Corrects overvoltage conditions to 520V (50% load) and 478V (100% load)

Undervoltage Correction Corrects brownout conditions to 110V (50% load) / 305V (100% load)

USER INTERFACE, ALERTS & CONTROLS

Front Panel LCD Display LCD DISPLAY: offers a variety of g

UPS Shipping Dimensions (hwd /

  1. cm) 106.02 x 38.00 x 92.00

Shipping Weight (lbs.) 430

Shipping Weight (kg) 195

Cooling Method Fans

UPS Housing Material Steel

UPS Power Module Dimensions

(Height x Width x Depth, mm) 862 x 250 x 813

UPS Shipping Dimensions (Height x

Width x Depth, mm) 1060 x 380 x 920

Primary UPS Height (mm) 861

Primary UPS Width (mm) 249

Primary UPS Depth (mm) 813

Shipping Height (mm) 1060

Shipping Width (mm) 380

Shipping Depth (mm) 920

ENVIRONMENTAL

Operating Temperature Range 0 to +40C (32-104F)

Storage Temperature Range 0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery

Relative Humidity 5 to 95%, non-condensing

Operating Elevation (ft.) < 3000ft (Capacity de-rates by 1% for every 330ft over 3000)

Audible Noise <65dBA front side 1M

Operating Elevation (m) < 1000m (Capacity de-rates by 1% for every 100m over 1000)

COMMUNICATIONS

Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Network Monitoring Port Description Card accessory slot also supports network interface and relay card options

Communications Cable DB9 cabling included

LINE / BATTERY TRANSFER

Transfer Time Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery

to AC mode

Low Voltage Transfer to Battery

Power (Setpoint) 110V (50% load) / 305V (100% load)

High Voltage Transfer to Battery

Power (Setpoint) 520V (50% load) / 478V (100% load)

Grounding Lug Yes

Cold Start (Startup in Battery Mode

During a Power Failure) Cold-start operation supported

High Availability UPS Features Automatic inverter bypass; Manual bypass switch

Green Energy-Saving Features High efficiency economy mode operation

CERTIFICATIONS

UPS Certifications CE

UPS Certification Details EN 62040-1-1 (Safety); EN 62040-2

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Tripp Lite SVT20KX UPS”

There are no reviews yet.

Got a question related to this product? Ask it here.


 